In the commissioning of the motor stator winding machine, at first, the winding is still good, and then there is a broken line this is what causes?
Briefly summarized as follows:
1. Possible line barrel placement problems, may also be stuck in the line, pay attention to check the line barrel has no defects.
2. Motor stator winding machine tensioner settings have a problem, the tension is set too large, easy to cause line breakage, generally have a tension table can be checked against.
3. Winding molds and nozzles correspond to the wrong, may also cause wire breakage.
4. Motor stator winding machine program parameters are not set properly, the winding speed is too fast, no start slow winding, etc. will cause breakage.
5. It is also possible that the middle guard plate is not installed in a good position, and the lower line scrapes the steel sheet.
6. The motor stator winding lineup mechanism is not precise enough, and the workmanship is rough, which may also lead to the deviation of the wire breakage problem.
The above is the motor stator winding wire breakage reasons, understand these reasons, in order to better use the winding machine to improve production capacity.