How to analyze and troubleshoot faults in motor rotor end plate commutator integrated machines?

To analyze and troubleshoot faults in motor rotor end plate commutator integrated machines, follow these steps:

1、Software troubleshooting:

If the software is unstable or malfunctioning, first check whether the software is a new version, if not, update it. At the same time, check whether the software settings are correct to ensure that all parameters are in line with production requirements.

微信截图_20241101115533.png

2、sensor positioning problems:

If the sensor can not accurately locate the position of the rotor commutator, check whether the sensor is clean and whether the distance value is set correctly. If the sensor is damaged, you need to replace the sensor with a new one.


3、automation control problems:

For automation control system response delay or non-response problems, check the hardware connections of the control system to ensure that all connections are firm and reliable. At the same time, check whether there are bugs in the software program, if necessary, carry out software updates or reset the system.


4、Data transmission problems:

If there are delays or errors in data transmission between devices, check the network connection and data transmission lines to make sure there is no physical damage or connection problems.


5、user interface problems:

If the operator interface is slow to respond or inoperable, restart the operator interface or the entire system and check if there are software updates that need to be installed. If the problem persists, you may need to check the operating system or contact technical support.


6、 program errors:

For error prompts or crashes that occur during program operation, check the program logs for error codes and related error messages. Troubleshoot according to the error prompts.


7、The motor can not rotate after power on, but there is no abnormal noise, nor odor and smoke:

Check the power circuit switch, fuse, junction box at whether there is a broken point, repair; check the fuse type, the reason for melting, replace the new fuse; adjust the relay setting value with the motor; correct the wiring.


8、The motor does not rotate after the power is turned on, and then the fuse is blown:

Check whether there is a phase of the knife gate is not closed, can be a phase of the power circuit disconnection; to rule out the reverse fault; to find out the short circuit point, to be repaired; to rule out the grounding; to find out the misconnection, to be corrected; replacement of fuses; to rule out the grounding point.


9、after power on the motor does not rotate with a buzzing sound:

Identify the broken point to be repaired; check the polarity of the winding; determine whether the winding end is correct; tighten the loose wiring screws, use a multimeter to determine whether the joints are false, to be repaired; load shedding or to find out and exclude mechanical faults.


Through the above steps, the motor motor rotor pressure end plate commutator integrated machine can be effectively fault analysis and elimination, to ensure the stable operation of the equipment.


Case:

Fault case: unstable software operation

Failure phenomenon: in the use of motor motor rotor pressure end plate commutator integrated machine, software operation is not stable, often appear fault or error prompts, resulting in production interruption.


Solution:

  • Check the software version: first check whether the software is a new version, if not, update.

  • Check the software setting: confirm whether the software setting is correct or not, make sure all the parameters are in line with the production requirements.


By following the above steps, you can effectively resolve the issue of unstable software operation in the motor rotor end plate commutator integrated machine, ensuring the normal operation of the equipment and production efficiency.


※ If the above methods still fail to resolve the equipment malfunction, please contact the technical specialist at Xinhui Electromechanical Equipment Co., Ltd. via the chat tool on this page for assistance.